Mes Notices

600 000 notices et 900 000 pièces détachées électroménager

Notice YAMAHA PW3000MA

Télécharger la notice

Extrait du mode d'emploi YAMAHA PW3000MA

Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

0A PIN 5 ­15V 5. 0A PIN 6 +12V 5. 0A PIN 9 +48V 0. 2A DISCONNECT DISCONNECT D DC OUTPUT connector Connect this connector to the mixer to supply power to it. The PW3000MA power supply can be used with the following mixers. M2500-56C M3000A-56C M2500-48C M3000A-40C M2500-40C M3000A-32 M2500-32 M3000A-24 M2500-24 4 sSpecifications Power Requirements USA and Canada: 120 V, 60 Hz Europe: 230 V, 50 Hz Others: 240 V, 50 Hz USA and Canada: 500 W, 600 VA Europe: 500 W Others: 500 W 480 mm x 103. 5 mm x 455 mm 15 kg Parallel connection cable (1 m) Power Consumptions Dimension (W x H x D) Weight Accessories sPower supply cable pin configuration Pin No. 1 2 3 4 5 6 7 8 9 10 Signal name Power supply remote +15 V ±15 V GND +48 V GND ­15 V +12 V +12 V GND/ power supply remote Power supply remote +48 V FRAME GND 7 10 3 6 9 2 5 8 1 4 4 8 1 5 9 2 6 10 3 7 Power supply connector DC PARALLEL INPUT DC OUTPUT sDimensions 405. 6 D:455 W:480 49. 4 308 H:103. 5 88 Units: mm · Specifications and appearance are subject to change without notice for improvement. 8 292 5 POWER SUPPLY Mode d'emploi Français sPrécautions · Branchez le cordon d'alimentation du bloc d'alimentation à une prise du type décrit dans ce Mode d'emploi ou sur le bloc d'alimentation. Le non-respect de ces consignes peut provoquer un incendie ou une électrocution · Ne placez pas le bloc d'alimentation à un endroit soumis à une chaleur excessive ou en plein soleil. Cela peut provoquer un incendie. · Ne placez pas le bloc d'alimentation dans un endroit excessivement humide ou poussiéreux. Cela peut provoquer un incendie ou une électrocution. · Evitez de brancher plusieurs appareils sur la même prise. Celle-ci risque d'être surchargée ce qui peut provoquer un incendie ou une électrocution. Cela peut en outre altérer les performances d'autres appareils. · N'essayez pas de modifier le bloc d'alimentation. Cela peut provoquer un incendie ou une électrocution. · La température de fonctionnement de la console de mixage peut se situer entre 5°C et 35°C (41°F et 95°F). · Coupez tous les appareils audio ainsi que les enceintes lors des branchements. Veuillez consulter le mode d'emploi de chaque appareil. Servez-vous de câbles adéquats et effectuez les branchements selon les consignes données. [...] Leaving the power supply unit connected is a fire hazard. · Do not use benzene, thinner, cleaning detergent, or a chemical cloth to clean the power supply unit. Use only a soft, dry cloth. · The power supply unit uses high-frequency digital circuits that may cause interference on radios and televisions placed close to it. If interference does occur, relocate the affected equipment. For European Model Purchaser/User information specified in EN55103-1 and EN55103-2. Inrush Current: 44A Conformed Environment: E1, E2, E3 and E4. 3 sFront panel 1 2 POWER OPERATION MONITOR +48V +12V +15V ­15V POWER SUPPLY NORMAL ON/ OFF sRear panel 5 DC PARALLEL INPUT CONNECT 4 DC OUTPUT CONNECT PIN 2 +15V 5. 0A PIN 5 ­15V 5. 0A PIN 6 +12V 5. 0A PIN 9 +48V 0. 2A DISCONNECT DISCONNECT 3 The PW3000MA power supply should be installed in a well ventilated location. In particular, the front and rear panels must not be blocked, since the ventilation path passes through them. E DC PARALLEL INPUT connector This connector allows two PW3000MA units to be connected in parallel. As shown in the following diagram, use the included parallel connection cable to make connections. In this case, the two PW3000MA units will each supply 50% of the power in normal operation. Even in the unlikely event that one of the PW3000MA units failed, the other PW3000MA will supply 100% of the power, ensuring an uninterrupted power supply. DC POWER INPUT A POWER ON/OFF switch After connections to the mixer have been completed, turn this switch on to supply power to the mixer. B Operation monitor These LEDs indicate the status of the four types of power that are being supplied to the mixer. Normally (i. , when no malfunction has occurred), the green LEDs (NORMAL) will light. If a malfunction occurs, the LED for that section of the power supply will go dark. Turn the power off and wait for a time before turning the power on again. If the same LED(s) are dark, contact a Yamaha service center. PW3000MA DC PARALLEL INPUT CONNECT DC OUTPUT DC OUTPUT CONNECT PIN 2 +15V 5. 0A PIN 5 ­15V 5. 0A PIN 6 +12V 5. 0A PIN 9 +48V 0. 2A DISCONNECT DISCONNECT C GND terminals This is the grounding screw terminal. If hum or noise occurs, ground (earth) the unit via this jack, or try connecting it to the chassis of the other device. [...]..

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre YAMAHA PW3000MA : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Samedi 10 Octobre 2008.

Vous pouvez télécharger les notices suivantes connexes à ce produit :

   YAMAHA PW3000MA (304 ko)

Liens commerciaux