Mes Notices

600 000 notices et 900 000 pièces détachées électroménager

Notice TOSHIBA RBC-RD2-PE - INSTALLATION MANUAL

Télécharger la notice

Extrait du mode d'emploi TOSHIBA RBC-RD2-PE

Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

The RD1 is designed to be installed next to the indoor unit, with the remote sensor and audible alarm located at a low level and preferably under the indoor unit. The RD1 is designed for use with MMS indoor units and RAV `4' Series AI indoor units only. The second model is the RBC-RD2-PE. The (RD2) is designed for use in the modular multi outdoor unit. The unit will be located within the compressor housing, and it has an internal sensor. The RD2 can only be fitted to the MMS outdoor unit. The functionality of both systems will be covered in indoor & outdoor operation section of this manual. G G G G Unit Setup G There are two control PCB's inside the refrigerant detector, each with jumpers which enable specific functions to be enabled/disabled. The diagrams below show the locations of these jumpers. AJP + sig ­ mute + buzzer AI ALARM BJP N L control board ABC JP Sub PCB 6 GB Unit Setup The function of the jumpers are listed below: Jumper A B C JP AJP BJP RBC-RD1-PE Not Used Not Present Not Used Disable unit shutdown Close Alarm contacts Present RBC-RD2-PE Not Used Present Not Used Disable unit shutdown Close Alarm contacts Not Present From the above the only jumpers which are user selectable are "JP" and "AJP". G JP: If this jumper is removed the indoor unit or outdoor system will not shutdown (hence B6 ­ indoor, and 04 ­ outdoor fault codes would not be generated). Removing this jumper is not recommended unless it is critical that the system must remain operating. AJP: If this jumper is fitted, then the Alarm (Solenoid valve relay) contacts are closed. This is not depended on the unit being powered. The primary reason for this jumper is during commissioning. If valves are fitted, then the air conditioning system can run, even when the detector is not commissioned or powered. All other jumpers must be fitted as shown in the table for correct system operation. G G 7 GB System Overview G G A typical RBC-RD1-PE installation would be in a hotel room or office. [...] 63-65 Elektrische Bedrading ­ RD1. 66-67 Elektrische Bedrading ­ RD2. 68-69 NL 3 GB Caution This manual contains the installation instructions for the Refrigerant Leak detector units RBC-RD1-PE and RBC-RD2-PE. Please read these instructions thoroughly before starting the installation work. This equipment should only be installed by suitably trained operatives. Incorrect installation by unqualified personnel may result in the refrigerant detector units not operating correctly, electric shock or fire. In all cases ensure safe working practices are followed. Observe precautions for persons in the vicinity of the works. Ensure that all local, national and international regulations are satisfied. Before commencing the installation, ensure all relevant electrical supplies are isolated. Carefully unpack the equipment and check for damage or shortages. Please report any damage or shortages immediately. If solenoid valves are to be used, ensure they are designed to be used with high/low temperatures and pressures of the refrigerant and they are capable of bi-directional flow. The refrigerant detector units comply with the following EC Directives: 73/23/EEC ­ Low Voltage Directive 89/336/EEC ­ Electro Magnetic Compatibility Accordingly the refrigerant detector units are designated for use in commercial and industrial environments. [...]..

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre climatiseur TOSHIBA RBC-RD2-PE : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Vendredi 2 Février 2011.

Liens commerciaux