Notice TOSHIBA RAV-SM1603ATZ-E - INSTALLATION MANUAL
Extrait du mode d'emploi TOSHIBA RAV-SM1603ATZ-E
Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.
The refrigerant used in the air conditioner is harmless. Generally, the refrigerant does not leak. However, if the refrigerant leaks in a room and a heater or stove burner in the room catches fire, it may generate toxic gas. When you ask service personnel for repairing refrigerant leakage, confirm that the leakage portion has been completely repaired. · Conform to the regulations of the local electric company when wiring the power supply. Inappropriate grounding may cause electric shock. · Do not install the air conditioner in a location subject to a risk of exposure to a combustible gas. If a combustible gas leaks, and stays around the unit, a fire may occur. · Install the refrigerant pipe securely during the installation work before operating the air conditioner. If the compressor is operated with the valve open and without the refrigerant pipe, the compressor sucks air and the refrigeration cycle is overpressurized, which may cause a burst or injury. · For the refrigerant recovery work (collection of refrigerant from the pipe to the compressor), stop the compressor before disconnecting the refrigerant pipe. If the refrigerant pipe is disconnected while the compressor is working with the valve open, the compressor sucks air and the refrigeration cycle is overpressurized, which may cause a burst or injury. CAUTION New Refrigerant Air Conditioner Installation · THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT DESTROY OZONE LAYER. · The characteristics of R410A refrigerant are ; easy to absorb water, oxidizing membrane or oil, and its pressure is approx. 6 times higher than that of refrigerant R22. Accompanied with the new refrigerant, refrigerating oil has also been changed. Therefore, during installation work, be sure that water, dust, former refrigerant, or refrigerating oil does not enter the refrigerating cycle. · To prevent charging an incorrect refrigerant and refrigerating oil, the sizes of connecting sections of charging port of the main unit and installation tools are changed from those for the conventional refrigerant. · Accordingly the exclusive tools are required for the new refrigerant (R410A). · For connecting pipes, use new and clean piping designed for R410A, and please care so that water or dust does not enter. [...] · Do not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches. · After unpacking the unit, examine it carefully if there are possible damage. · Do not install in a place that might increase the vibration of the unit. · To avoid personal injury (with sharp edges), be careful when handling parts. · Perform installation work properly according to the Installation Manual. Inappropriate installation may result in water leakage, electric shock or fire. · When the air conditioner indoor unit is installed in a small room, provide appropriate measures to ensure that the concentration of refrigerant leakage occur in the room does not exceed the critical level. · Tighten the flare nut with a torque wrench in the specified manner. Excessive tightening of the flare nut may cause a crack in the flare nut after a long period, which may result in refrigerant leakage. · Wear heavy gloves during the installation work to avoid injury. · Install the air conditioner securely in a location where the base can sustain the weight adequately. · Perform the specified installation work to guard against an earthquake. If the air conditioner is not installed appropriately, accidents may occur due to the falling unit. · If refrigerant gas has leaked during the installation work, ventilate the room immediately. If the leaked refrigerant gas comes in contact with fire, noxious gas may generate. · After the installation work, confirm that refrigerant gas does not leak. If refrigerant gas leaks into the room and flows near a fire source, such as a cooking range, noxious gas might generate. · Electrical work must be performed by a qualified electrician in accordance with the Installation Manual. Make sure the air conditioner uses an exclusive power supply. An insufficient power supply capacity or inappropriate installation may cause fire. · Use the specified wires for wiring connect the terminals securely fix. To prevent external forces applied to the terminals from affecting the terminals. 3-EN 3 Digital Inverter Outdoor Unit Installation Manual WARNING · When the air conditioner cannot cool or heat a room well, contact the dealer from whom you purchased the air conditioner as refrigerant leakage is considered as the cause. [...]..
Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre climatiseur TOSHIBA RAV-SM1603ATZ-E : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Vendredi 2 Février 2011.