Notice TOSHIBA RAS-16SKV2-E
Extrait du mode d'emploi TOSHIBA RAS-16SKV2-E
Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.
This is normal because the cracking sound may be caused by expansion/ contraction of plastic. Note: Item 2 to 6 for Heating model Air conditioner operating conditions Temp. Operation Outdoor Temperature 15°C ~ 24°C 10°C ~ 46°C 10°C ~ 46°C Room Temperature Less than 28°C 21°C ~ 32°C 17°C ~ 32°C ( or ) mark flashing. PT PL CZ CR HU NL GR SV FI · During the daily timer is activating, both arrows ( , ) are indicated. Note: · Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur. · The setting will be saved for the next same operation. 13 PRESET OPERATION Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction). Select your preferred operation. PRESET 2. Press and hold The P mark displays. PRESET for 3 seconds to memorize the setting. Press : Operate the preset operation. 14 AUTO RESTART OPERATION To automatically restart the conditioner after the power failure (Power of the unit must be on. ) Setting 1. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds) · Do not operate ON timer and OFF timer. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink) Heating Cooling Dry 21 TROUBLESHOOTING (CHECK POINT) The unit does not operate. · The power main switch is turned off. · The circuit breaker is activated to cut off the power supply. · Stoppage of electric current · ON timer is set. · · · · Cooling or Heating is abnormally low. The filters are blocked with dust. The temperature has been set improperly. The windows or doors are opened. The air inlet or outlet of the outdoor unit is blocked. · The fan speed is too low. · The operation mode is FAN or DRY. NO DK RO BG EE LV SK SI 15 QUIET OPERATION To operate at super low fan speed for quiet operation (except in DRY mode) QUIET : Start and stop the operation. Press Note: Under certain conditions, QUIET operation may not provide adequate cooling or heating due to low sound features. 22 REMOTE CONTROL A-B SELECTION To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly. Remote Control B Setup. [...] 18 MAINTENANCE Firstly, turn off the circuit breaker. Filter Reset (Some models only) FILTER lamp lights on; the filter must be cleaned. To turn off the lamp, push the RESET button on the indoor unit or the FILTER button on the remote control. Indoor Unit and Remote Control · Clean the indoor unit and the remote control with a wet cloth when needed. · No benzine, thinner, polishing powder or chemically-treated duster. 12 TIMER OPERATION Setting the ON Timer Setting the OFF Timer Press OFF EN 19 SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY) To protect bad smell caused by the humidity in the indoor unit. If the button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for other 20 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit. To stop the unit immediately, press the 3 times within 30 seconds. Note: · SELF CLEANING operation is default setting from factory. · To cancel this function, please contact the supplying retail dealership. 1 2 3 Press ON : Set the desired ON timer. : Set the desired OFF timer. ES FR IT DE Press Press SET : Set the timer. : Cancel the timer. Press Press SET : Set the timer. : Cancel the timer. CLR CLR Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis. Setting Daily Timer 1 Press ON : Set the ON timer. 3 Press SET. 2 Press OFF : Set the OFF timer. 4 Press SET button during the 20 OPERATION AND PERFORMANCE 1. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop. Automatic defrosting: Fans will stop during defrost operation. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. [...]..
Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre climatiseur TOSHIBA RAS-16SKV2-E : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Vendredi 2 Février 2011.
Vous pouvez télécharger les notices suivantes connexes à ce produit :
TOSHIBA RAS-16SKV2-E DOCUMENTATION COMMERCIALE (1112 ko)
TOSHIBA RAS-16SKV2-E SERVICE MANUAL (12593 ko)
Vos avis sur le TOSHIBA RAS-16SKV2-E
Donne toute satisfaction pour chauffer un grand volume, donne toute satisfaction. Bon rapport qualite prix.