Mes Notices

600 000 notices et 900 000 pièces détachées électroménager

Notice TOSHIBA RAS-13SKHP-ES

Télécharger la notice

Extrait du mode d'emploi TOSHIBA RAS-13SKHP-ES

Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

Note: · Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 5 minutes will occur. · The setting will be saved for the next same operation. 13 PRESET OPERATION Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction). Select your preferred operation. PRESET Air conditioner operating conditions Temp. Operation Heating Cooling Dry Outdoor Temperature ­ 0°C ~ 24°C 5°C ~ 43°C 5°C ~ 43°C Room Temperature Less than 27°C 2 °C ~ 32°C 7°C ~ 32°C for 3 seconds to memorize the setting. The P mark 2. Press and hold displays. PRESET 3. Press : Operate the preset operation. 14 AUTO RESTART OPERATION 21 To automatically restart the conditioner after the power failure (Power of the unit must be on. ) Setting. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds) · Do not operate ON timer and OFF timer. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink) TROUBLESHOOTING (CHECK POINT) The unit does not operate. Cooling or Heating is abnormally low. · The filters are blocked with dust. · The temperature has been set improperly. · The windows or doors are opened. · The air inlet or outlet of the outdoor unit is blocked. · The fan speed is too low. · The operation mode is FAN or DRY. · The power main switch is turned off. · The circuit breaker is activated to cut off the power supply. · Stoppage of electric current · ON timer is set. 15 QUIET OPERATION QUIET To operate at super low fan speed for quiet operation (except in DRY mode) Press : Start and stop the operation. Note: Under certain conditions, QUIET operation may not provide adequate cooling or heating due to low sound features. 22 16 REMOTE CONTROL A-B SELECTION COMFORT SLEEP OPERATION COMFORT SLEEP To separate using of remote control for each indoor unit in case of 2 air conditioner are installed nearly. Remote Control B Setup. Press RESET button on the indoor unit to turn the air conditioner ON. Point the remote control at the indoor unit. Push and hold CHK button on the Remote Control by the tip of the pencil. "00" will be shown on the display. [...] button is pressed once during "Cool" or "Dry" mode, the fan will. If the continue to run for other 20 minutes, then it will turn off automatically. This will reduce the moisture in the indoor unit. 3 times within 30 seconds. To stop the unit immediately, press the Note: · SELF CLEANING operation is default setting from factory. · To cancel this function, press and hold the reset button on the indoor unit for 20 seconds. The SELF CLEANING operation will be cancelled. (5 beep sound but OPERATION lamp does not blink) · Do the same to set this function again. (5 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds) · AUTO RESTART operation will be cancelled by setting or cancellation of SELF CLEANING operation. Set it again if necessary. 12 TIMER OPERATION Setting the ON Timer Setting the OFF Timer Press Press Press OFF 1 2 3 Press Press Press ON : Set the desired ON timer. : Set the timer. : Cancel the timer. : Set the desired OFF timer. : Set the timer. : Cancel the timer. EN SET SET CLR CLR Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis. Setting Daily Timer 20 : Set the ON timer. OPERATION AND PERFORMANCE. Three-minute protection feature: To prevent the unit from being activated for 3 minutes when suddenly restarted or switched to ON. Preheating operation: Warm up the unit for 5 minutes before the heating operation starts. Warm air control: When the room temperature reaches the set temperature, the fan speed is automatically reduced and the outdoor unit will stop. Automatic defrosting: Fans will stop during defrost operation. Heating capacity: Heat is absorbed from outdoors and released into the room. When the outdoor temperature is too low, use another recommended heating apparatus in combination with the air conditioner. Consideration for accumulated snow: Select the position for outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. Some minor cracking sound may occur when unit operating. This is normal because the cracking sound may be caused by expansion/contraction of plastic. Note: Item 2 to 6 for Heating model 1 Press ON 3 Press SET. 2 Press OFF : Set the OFF timer. 4 Press button during the ( or ) mark flashing. [...]..

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre climatiseur TOSHIBA RAS-13SKHP-ES : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Vendredi 2 Février 2011.

Vous pouvez télécharger les notices suivantes connexes à ce produit :

   TOSHIBA RAS-13SKHP-ES INSTALLATION MANUAL (784 ko)
   TOSHIBA RAS-13SKHP-ES SERVICE MANUAL (5516 ko)