Notice PHILIPS HP 3631
Extrait du mode d'emploi PHILIPS HP 3631
Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.
4 Sit or lie down at the right distance from the appliance. At a distance of 30-40 cm to the body, the InfraCare treats an area of about 40 cm by 30 cm (w x h). At a larger distance, the area treated becomes larger and the infrared light and therefore the heat less intense. At a smaller distance, the area treated is smaller and the infrared light and therefore the heat more intense. - Make sure the distance between your body and the appliance is large enough to prevent accidental contact with the hot filter. - choose a distance at which the heat is comfortable and increase the distance if the heat becomes too intense. - EnglisH Note:The heat of the appliance does not reach its full intensity until several minutes after you switch on the appliance. This does not mean, however, that the appliance is not effective during these first minutes. Duration of treatment The duration of the treatment depends on the type of treatment and the person to be treated. Treatment of a single muscle or joint should last approximately 15 minutes. If necessary, the treatment can be repeated several times a day. A longer treatment time than 15 minutes does not lead to better results. You can repeat the course of several treatments a day on several consecutive days to get a result. If there is no improvement after 6-8 treatments, stop using the appliance and consult your doctor. For chronic problems, the appliance can be used for longer periods of time, as long as you follow the instructions given in the `Warning' section in chapter `Important'. using the infracare 1 Put the mains plug in the wall socket. 2 Press the on/off button to switch on the appliance (Fig. , The green power-on light goes on. 9 3 Press the timer button to set the desired treatment time (0-99 minutes). Keep the button pressed to adjust the time more quickly. , The set time is shown on the display. , Two seconds after you release the timer button, the timer starts to count down in minutes. The last minute is displayed in seconds. During countdown, the remaining time flashes on the display. Note:To change the set time during treatment, keep the timer button pressed for 2 seconds until `00' appears on the display. Then use the timer button to set a new treatment time. , When the set time has elapsed, you hear an intermittent beep and `00' flashes on the display. Note:The timer does not switch off the appliance. It only signals that the set time has elapsed. [...] If handled properly and according to the instructions in this user manual, the appliance is safe to use based on scientific evidence available today. 8 EnglisH using the appliance the effects of the infracare The InfraCare produces infrared light, which penetrates deeply into the skin and warms the tissues. The warmth modulates the neuronal signals to the brain and thus reduces pain. Warmth also stimulates the blood circulation and dilates the blood vessels, which accelerates the transport of substances necessary to rebuild and nourish the body's tissues. Furthermore, infrared light speeds up the metabolic process and the removal of waste substances from the body. Because it makes tissue more pliable, warmth also reduces stiffness and makes joints more flexible. Because of these effects, treatment with the InfraCare can temporarily relieve pain due to muscle and joint problems. Note: Please read the `Warning' section in chapter `Important' and follow the instructions given there before you use the appliance. applications therapeutic applications The InfraCare is a local warmth therapy appliance. Possible therapeutic applications: - Treatment of occasional or chronic muscle pains, stiff muscles and stiff joints. - Treatment of lower-back ache. other applications You can also use the InfraCare for the following purposes: - Muscle relaxation - Preparation for a massage Note: For more information about the health benefits, see www. philips. com, search word InfraCare (Fig. Preparing for use 1 Fully unwind the mains cord. 2 Place the appliance on a stable, level surface and make sure there is at least 25cm free space around it to prevent overheating (Fig. The appliance can be used in many different ways. Below you find some examples. - To treat a sore shoulder, a sore neck or part of your upper back area, place the appliance on a table and tilt the lamp housing backwards. Sit down on a chair or stool with your back towards the lamp (Fig. - To treat a lower-back ache, place the appliance on a table beside a chair. Sit down on a chair or stool with your back towards the lamp (Fig. - To treat a sore elbow, place the appliance on a table and sit down beside it (Fig. - To treat a sore knee, place the appliance on a bedside table and lie down on the bed with one leg pulled up towards the lamp (Fig. [...]..
Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre luminothérapie PHILIPS HP 3631 : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Lundi 12 Décembre 2011.