Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

· A place full of saline atmosphere (coastal area) or sulfide gas (hot-spring area) (Special maintenance is required. ) · A place subject to oil, vapor, oily smoke, or corrosive gas · A place where organic solvent is used · A place where high-frequency equipment (including inverter equipment, private power generator, medical equipment, and communication equipment) is used (Installation in this place may cause malfunction of the Air to Water Heat Pump, abnormal control or problems due to noise to such equipment. ) · A place where the discharged air of the outdoor unit blows against the window of the neighboring house · A place where the operating noise of the outdoor unit is transmitted · When the outdoor unit is installed in an elevated position, be sure to secure its feet. · A place where the drain water does not make any problem. 2) Supposing the wind direction during the operation season of the Air to Water Heat Pump, install the unit so that the discharge port is set at right angle to the wind direction. Strong wind Strong wind · When using an Air to Water Heat Pump under low outside temperature condition (Outside temp. :-5 °C or lower) with COOL mode, prepare a duct or wind shield so that it is not affected by the wind. Wind shield Wind shield Wind shield 7-EN ­8­ Air to Water Heat Pump Outdoor Unit Installation Manual Necessary Space for Installation Obstacle at rear side Upper side is free 1. Single unit installation (Unit:mm) Obstacle at front side Upper side is free 1. Single unit installation 150 or more 2. [...] WARNING · Ask an authorized dealer or qualified installation professional to install/maintain the Air to Water Heat Pump. Inappropriate installation may result in water leakage, electric shock or fire. · Be sure to connect earth wire. (grounding work) Incomplete grounding cause an electric shock. Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires for telephone wires. · Turn off the main power supply switch or breaker before attempting any electrical work. Make sure all power switches are off. Failure to do so may cause electric shock. Use an exclusive power circuit for the Air to Water Heat Pump. Use the rated voltage. · Connect the connecting wire correctly. If the connecting wire is connected in a wrong way, electric parts may be damaged. · When moving the Air to Water Heat Pump for the installation into another place, be very careful not to enter any gaseous matter other than the specified refrigerant into the refrigeration cycle. If air or any other gas is mixed in the refrigerant, the gas pressure in the refrigeration cycle becomes abnormally high and it may resultingly causes pipe burst and injuries on persons. · Do not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches. · After unpacking the unit, examine it carefully if there are possible damage. · Do not install in a place that might increase the vibration of the unit. · To avoid personal injury (with sharp edges), be careful when handling parts. · Perform installation work properly according to the Installation Manual. Inappropriate installation may result in water leakage, electric shock or fire. · When the Air to Water Heat Pump hydro unit is installed in a small room, provide appropriate measures to ensure that the concentration of refrigerant leakage occur in the room does not exceed the critical level...

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre réfrigérateur-congélateur LG GR-P247EQ : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Mardi 10 Octobre 2008.

Vous pouvez télécharger les notices suivantes connexes à ce produit :

   LG GR-P247EQ (4116 ko)

Vos avis sur le LG GR-P247EQ

 Excellent appareil nous le possédons depuis 8 ans et aucun problème, pas mal. Seul problème : si on coupe l'arrivée d'eau pendant le fonctionnement, celle-ci gèle et la remise en route nécessite un dégivrage assez long, rien à rajouter, bon rapport qualité prix.

Liens commerciaux


Joint pour réfrigérateur/congélateur LG GR-P247EQ22,72 € *
22,72 € *
★★★★★
Thermostat pour réfrigérateur/congélateur LG GR-P247EQ8,12 € *
8,12 € *
★★★★★
Clayette pour réfrigérateur/congélateur LG GR-P247EQ13,20 € *
13,20 € *
★★★★★
Poignée pour réfrigérateur/congélateur LG GR-P247EQ7,33 € *
7,33 € *
★★★★★
Bac pour réfrigérateur/congélateur LG GR-P247EQ17,89 € *
17,89 € *
★★★★★
Résistance pour réfrigérateur/congélateur LG GR-P247EQ12,34 € *
12,34 € *
★★★★★
Ventilateur pour réfrigérateur/congélateur LG GR-P247EQ10,62 € *
10,62 € *
★★★★★
Filtre pour réfrigérateur/congélateur LG GR-P247EQ5,64 € *
5,64 € *
★★★★★
Ampoule pour réfrigérateur/congélateur LG GR-P247EQ3,68 € *
3,68 € *
★★★★★
Toutes les pièces détachées

* Prix indicatif de vente, le prix exact sera affiché après que vous ayez saisi la référence de votre appareil.