Mes Notices

600 000 notices et 900 000 pièces détachées électroménager

Notice LG GR-B197DVQA

Télécharger la notice

Extrait du mode d'emploi LG GR-B197DVQA

Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

Note: All dimensions in (mm) 500 500 Piping Connecting Piping 18 Installation Piping Free Branching System The following five branching systems are available to increase the flexibility of refrigerant piping design. GB 1 Line branching system Outdoor units Branching joint Remote controller Indoor units 2 Header branching system Outdoor units Branching header Remote controller Indoor units 3 Header branching system after line branching Outdoor units Branching joint Branching header Remote controller Indoor units 4 Line branching system after header branching Header branching system after header branching Outdoor units Branching header 5 Branching joint Indoor units Remote controller 19 Installation Piping WARNING! During installation ­ if the refrigerant gas leaks, ventilate the room. After installation ­ check for gas leakages. If refrigerant gas comes into contact with fire ­ noxious gas may result! Connecting Refrigerant Pipes 1. To access the refrigerant piping connections and electrical wiring terminals, remove the 7xM5 securing bolts in the front panel. To remove the panel, lift it up and away from its hanging tabs ­ See diagram. The refrigerant pipes can be routed forwards, downwards or sideways. If the pipes are routed forwards, make sure they exit through the Piping/Wiring Panel ­ (remove knock out section) and allow at least 500mm between the Outdoor Unit and the main pipe connecting it to the Indoor Unit. This is for servicing access. (Replacing the compressor, for example, requires a space of at least 500mm. If the pipes are routed downwards, remove the knockout section in the baseplate of the Outdoor Unit. This will enable access. They can then be connected to the left or right, or the rear side. (Leading pipe of the balancing should be within 4m. ) Notes: 1. When brazing, use nitrogen. [...] Allocation standard of Model name OUTDOOR MM­A0280HT Modular Multi A ­ Outdoor 0280 ­ 28. 0kW (10HP) 0224 ­ 22. 4kW (8HP) 0160 ­ 16. 0kW (6HP) C ­ Cooling H ­ Heating T ­ Inverter X ­ Fixed Speed INDOOR MM­TU056 B ­ C (CR) ­ K (KR) ­ N ­ S (SR) ­ SB ­ TU ­ U ­ Built-In Duct Type Ceiling Type (IR Remote) High Wall Type (IR Remote) Carcase Type Low Wall Type (IR Remote) Built-In Slim Duct Type 2 Way Cassette Type 4 Way Cassette Type Modular Multi 028 042 056 080 112 140 ­ ­ ­ ­ ­ ­ 2. 8kW (1HP) 4. 2kW (1. 5HP) 5. 6kW (2HP) 8. 0kW (3HP) 11. 2kW (4HP) 14. 0kW (5HP) 2. Range of combined units No. of combined units Capacity range : 1 to 5 units : Equivalent to 14HP (0384kW type) to 46HP (1288kW) 3. Restriction for combination units (1) The Inverter Unit should have the maximum capacity among all units in that combination. (2) The 6HP fixed-speed unit is available only with the combination of 14HP and 22HP (It cannot be used for any other combination. Rated conditions Cooling Heating : Indoor air temperature 27°C DB/19°C WB Outdoor air temperature 35°C DB/25°C WB : Indoor air temperature 21°C DB/15. 5°C WB Outdoor air temperature 7°C DB/6° C WB 5. Mode Priority This Outdoor Unit is set to operate with the Heating mode taking precidence. This precidence can be switched between Heat and Cool mode using the DIP switch 07 on the Outdoor Unit Interface PCB (MCC-1343-01) as follows: ON OFF Heat Priority (factory set) ON OFF Cool Priority 6 Introduction Components 1. Outdoor Unit Inverter unit Corresponding HP 8HP Model name Cooling capacity (kW) Heating capacity (kW) 10HP 6HP 8HP 10HP Fixed-speed unit Appearance MM-A0224HT MM-A0280HT GR-B197DVQA MM-A0224HX MM-A0280HX 22. 5 GB 2. Outdoor Units (Combination of Outdoor Units) Corresponding HP 8HP 10HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 32HP 34HP 36HP 0440 0504 0560 0608 0672 44...

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre réfrigérateur-congélateur LG GR-B197DVQA : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Mardi 10 Octobre 2008.

Vos avis sur le LG GR-B197DVQA

 Bon materiel.

Liens commerciaux


Joint pour réfrigérateur/congélateur LG GR-B197DVQA22,72 € *
22,72 € *
★★★★★
Thermostat pour réfrigérateur/congélateur LG GR-B197DVQA8,12 € *
8,12 € *
★★★★★
Clayette pour réfrigérateur/congélateur LG GR-B197DVQA13,20 € *
13,20 € *
★★★★★
Poignée pour réfrigérateur/congélateur LG GR-B197DVQA7,33 € *
7,33 € *
★★★★★
Bac pour réfrigérateur/congélateur LG GR-B197DVQA17,89 € *
17,89 € *
★★★★★
Résistance pour réfrigérateur/congélateur LG GR-B197DVQA12,34 € *
12,34 € *
★★★★★
Ventilateur pour réfrigérateur/congélateur LG GR-B197DVQA10,62 € *
10,62 € *
★★★★★
Filtre pour réfrigérateur/congélateur LG GR-B197DVQA5,64 € *
5,64 € *
★★★★★
Ampoule pour réfrigérateur/congélateur LG GR-B197DVQA3,68 € *
3,68 € *
★★★★★
Toutes les pièces détachées

* Prix indicatif de vente, le prix exact sera affiché après que vous ayez saisi la référence de votre appareil.