Mes Notices
* Prix indicatif de vente, le prix exact sera affiché après que vous ayez saisi la référence de votre appareil.
Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.
Changing the lamp ? Before carrying out any work, the power supply to the hood must be turned off, either by unplugging it or by using the circuit breaker switch, 1. Remove the viewing port (fig. Change the halogen lamp G4-20W-12V. Replace the lamp assembly by carrying out the above operations in reverse order. 99625942_ML_A. qxd 23/06/03 10:50 Page 7 Cleaning your hood ? The power supply to the hood must be turned off either by removing the plug or by using the circuit breaker switch before you remove the metal filters. After cleaning, the metal filters must be refitted in conformity with the instructions. FILTER CARTRIDGE Remove the protective film before using the filter cartridge for the first time. ACTIVATED CARBON FILTER For hoods installed "recycling" mode. in MAINTENANCE VITAL EVERY MONTH VITAL EVERY YEAR To avoid all risks of fire. This filter traps fatty vapours and dust. This component plays an important part in ensuring the effectiveness of your hood. Use a commercial household cleaning product then rinse abundantly and dry. This cleaning can be carried out in your dishwasher in the vertical position (ensure that the cartridge never comes into contact with dirty crockery or silver tableware). GB WHY? This filter traps odours and must be changed at least once a year depending on your level of use. You should order these filters from your dealer (quoting the reference shown on the ID plate located inside the hood) and note the date the filter was changed. HOW ? Never use metal scouring pads, abrasive products or excessively stiff brushes. To clean the body and the lighting port, you should use only commercial household cleaning products diluted in water and then rinse using clean water, drying with a soft cloth. Dismantling the filter cartridge (fig. 10) Fitting the carbon filter (fig. 12) 1. Remove the cartridge. Place the new carbon filter on the cartridge inside the hood. Fit the two retention rods. Who should I contact ? Blemishes on the hood caused by abnormal use or cleaning with abrasive products which do not cause the appliance to cease functioning or which do not cause it to become unsuitable for use will not be dealt with by the manufacturer. Any repairs must be carried out by a qualified technician. [...] There is an adjustment margin of 10 mm in relation to the wall" AN EXCLUSIVE BRANDT FEATURE ". Before mounting your hood on the wall: - Remove the metal filter. - Remove the two screws (item 1). - Slightly unscrew the four screws, but do not remove them (item 2). - Pull the lower section outwards. - Assemble and mount the extractor duct as described. - Adjust the lower section to be in contact with the tiles or credence. - Tighten the four screws (item 2). - Install the metal filter. Detail of offset Détail décalage Wall/decorative feature décor / mur 10 mm GB item 2 item 1 item 2 99625942_ML_A. qxd 23/06/03 10:50 Page 6 Assembling the chimney Hood to be used with external evacuation: fig. 4 and 8 - Remove the two attachment clips provided for the transportation of the chimneys. - Remove the two attachment screws from the plastic deflector (in recycle mode only). - Attach the metal chimney bracket to the wall, also placing this against the ceiling (fig. Take care in aligning the 2 triangular slots on the metal bracket with the vertical line on the wall. - In the case of a flue with a diameter of 125 mm, use the adapter supplied (fig. If your exterior duct is below 125 mm, you must obligatorily connect your hood in recycling mode - Prepare your telescopic chimney taking care to block off the vents (fig. Fit the chimneys into one another as far as they will go. - Fit the upper part to the metal bracket. - Adjust the length of the telescopic chimney by bringing down the lower part and fitting it to the top of the hood. To ensure optimal use of your device, we advise that you connect a flue with a diameter of 150 mm (not supplied). Limit the number of angles and bends as far as possible, and keep the length of the flue to a minimum. In the event that the hood will be functioning using exterior evacuation, you should ensure a sufficient inlet of fresh air to avoid a pressure deficiency in the room. Hood to be used in "recycling" mode: fig. 5 and 9 - It is possible to remove the back flow valves. - Fit the plastic smoke deflector to the wall also placing this against the ceiling. Take care to centre the deflector vis-à-vis the vertical line drawn on the wall (fig. - Prepare your chimney taking care to place the vents toward the top to ensure that they are visible (fig. - Fit the upper part to the plastic deflector. [...]..
Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre hotte BRANDT AD389ZT1 : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Mercredi 1 Janvier 2008.
Hotte très esthétique et facile d'utilisation.
Envoyer vos modes d'emploi - Foire aux questions - Dernières recherches - Derniers ajouts - Sitemap - Contactez-nous - Conditions générales - Politique de cookies
Copyright - Tous droits réservés.
Les noms de marques cités appartiennent à leurs propriétaires respectifs.