Mes Notices

600 000 notices et 900 000 pièces détachées électroménager

Notice BELKIN AC ANYWHERE-#F5C412EF

Télécharger la notice

Extrait du mode d'emploi BELKIN AC ANYWHERE-#F5C412EF

Les instructions détaillées pour l'utilisation figurent dans le Guide de l'utilisateur.

If you are using the Inverter while the engine is off, we recommend you start the engine every hour and let it run for approximately 10 minutes to recharge the battery. We also recommend that the device plugged into the Inverter be turned off before turning over the engine. Although it is not necessary to unplug the Inverter when starting the engine, the Inverter may momentarily cease operation as the battery voltage decreases. When the Inverter is not supplying power, it draws very low amperage from the battery (< 0. 1 amps to < 0. 2 amps depending on the model) and may be left connected to the battery for up to 3 hours. However, we recommend the Inverter always be disconnected when not in use. Note: · Inverters will not operate with certain automotive systems unless the ignition is on. If the Inverter is not generating power, try turning the ignition to the accessory position. Automatic Shut-down and Related Safety Features: The Belkin 140 and 300-Watt Inverter models have a unique LED indicator warning light system that operates in conjunction with the automatic shut down feature. This indicator light operates as follows: RED - Overload/Low Battery Your Inverter will shut down automatically when any of the following problems occur: 1. The power input from the battery drops below 10. 4 volts. The power output from the battery exceeds 15 volts. The continuous draw of the device exceeds the design parameters of the Inverter. Battery Level Indicator Approximate State-of-charge 100% 75% 50% 25% 0% Open Circuit Battery Voltage 13. 7 < 10. 6 Additional Safety Features: 1. Automatic shutdown when the internal circuit temperature exceeds standard design parameters for safe operation. Continuous audible alarm: a. When the input power from the 12-volt power source drops to 11 volts. When the internal circuit temperature exceeds standard design parameters for safe operation. In the event of automatic shut-down or continuous alarm, turn the Inverter rocker switch to the OFF (O) position until the source of the related problem has been identified and resolved. Note: · The Belkin 300W model is equipped with a cooling fan that is only designed to run continuously while the Inverter is operating. Automatic shutdown caused by excess circuit temperature occurs when the cooling fan is unable to maintain the design parameters for safe operation of the Inverter. [...] 4 Volt 9. 8 Volt 10. 4 Volt 9. 8 Volt Installation: Power Source Requirements The power source must provides 12 Volts DC and must be able to supply the necessary current to operate the load. The power source may be a battery or a well-regulated 12V DC power supply. As a rough guideline, divide the power consumption of the load (in watt) by 12 (the input voltage) to obtain the current (in amperes) the power source must deliver. Example: Load is rated at 120 Watts; the power source must be able to deliver: (220/12) = 18. 3 Amps Making the Connection: The Belkin 140 and 300-Watt Inverters are designed to connect to your 12-volt battery through the cigarette lighter socket on your dashboard. To connect and use these Inverters, follow these easy steps: 1. Remove the cigarette lighter and push the adapter plug firmly into the socket. Make sure both the socket and adapter plug are clean and dry. Plug your appliance or equipment into the AC receptacle on the Inverter. Turn the Inverter rocker switch to the ON (l) position. Confirm that the LED Power Indicator light on the Inverter is glowing GREEN. This GREEN light indicates that your Inverter is "ready for action. Turn on your equipment for use. Don't Blow a Fuse: All Belkin Inverters are equipped with a spare fuse in case the original fuse should blow. Most blown fuses are the result of reverse polarity or a short circuit within the appliance or equipment being operated. With reasonable care, it should not be necessary to replace the fuse in your Inverter. To Replace a Fuse: Belkin 140-Watt / 300-Watt Inverter First, remove the power cord from the cigarette lighter socket. You will find fuse compartment is easily accessed at the back of the unit underneath the "lift-up" cover. Pull the blown fuse out, and insert the replacement. It is important to remember that to replace of fuse of the same type and rating as indicated. Make certain to correct the source of the overload that caused the blown fuse before turning your Inverter back ON. Open the fuse box cover 2. Replace the blown fuse with a new spade type fuse The Power Source: When the engine is off, most batteries will provide an ample power supply to the Inverter for one to two hours. [...]..

Téléchargez votre notice ! Téléchargement gratuit et sans inscription de tous types de documents pour mieux utiliser votre BELKIN AC ANYWHERE-#F5C412EF : mode d'emploi, notice d'utilisation, manuel d'instruction. Cette notice a été ajoutée le Mardi 2 Février 2009.

Vous pouvez télécharger les notices suivantes connexes à ce produit :

   BELKIN AC ANYWHERE-#F5C412EF annexe 1 (1338 ko)

Vos avis sur le BELKIN AC ANYWHERE-#F5C412EF

 N'a pas fonctionnã© du premier cout je suis ã  la recherche de la notice pour voir s'il faut le "charger", rien à battre.

Liens commerciaux